Careers in the Classroom
Back to kinds of work

Classroom example ICE Western

Show your class · 1 of 5

The question

Show your class · 2 of 5

How it works

Show your class · 3 of 5

Who does this work

Show your class · 4 of 5

Ways in

Show your class · 5 of 5

Ask the class

For you

About ICE Western

For you

Sources

How can a building bring fresh air in without losing all its heat?

ICE Western · Employer identifies industrial manufacturing facility in Calgary's South Foothills.

Graphic-novel illustration. Technician inspecting coils in a generic air-handling unit.

Where it fits

Pick your class
  • Science 10 · Unit B, outcome 3 — energy transfers in thermal devices

How it works

Schematic · not to scale

Fresh air can enter a building while some outgoing heat is recovered.

A circulating liquid carries heat between coils while exhaust air and incoming air remain separate.
  1. Warm exhaust air leaves a space while colder outdoor air enters in a winter example.

  2. A coil in the exhaust path transfers some heat to a circulating fluid.

  3. The fluid carries energy to a coil in the incoming-air path; the two air streams remain separate in this arrangement.

  4. Fans and the circulation system also require energy. Recovery can reduce part of the heating demand without recovering every unit of heat.

This is a run-around heat-recovery model, not every type of HVAC system. Do not depict dirty exhaust mixing directly with supply air or claim that a heat exchanger is a refrigerator. No glycol concentrations or equipment sizing instructions are needed.

The lesson, in the real world

Fresh air can enter a building while some outgoing heat is recovered.

  1. 1

    Warm exhaust air leaves a space while colder outdoor air enters in a winter example.

    Our explanation
  2. 2

    A coil in the exhaust path transfers some heat to a circulating fluid.

    Our explanation
  3. 3

    The fluid carries energy to a coil in the incoming-air path; the two air streams remain separate in this arrangement.

    Our explanation
  4. 4

    Fans and the circulation system also require energy. Recovery can reduce part of the heating demand without recovering every unit of heat.

    Our explanation
Source: icewestern.com — official website(opens in a new tab); icewestern.com — Glycol_Runaround.pdf(opens in a new tab); icewestern.com — careers(opens in a new tab); education.alberta.ca — science10.pdf(opens in a new tab)

Who does this work

Roles connected to this example

What each kind of work involves, the job titles to look for, and where to find postings in Calgary.

  • Mechanical design and prototyping

    Translate a need into a component or machine that can be built and tested. Designers use dimensions, material properties and constraints to evaluate alternatives.

    Classroom connection
    Geometry, forces and material properties shape real design trade-offs.

    Job titles to search
    Mechanical designer · Mechanical engineer

    Company supports HVAC manufacturing and service; SAIT supports general refrigeration/control work. The proposed tasks are interpreted, not verified current job titles at this plant.
  • Refrigeration and air-conditioning mechanic

    Install, maintain and troubleshoot equipment that moves heat and conditions air.

    Classroom connection
    A refrigeration system moves heat; it does not create cold as a substance.

    Job titles to search
    Refrigeration mechanic · HVAC technician

    Company supports HVAC manufacturing and service; SAIT supports general refrigeration/control work. The proposed tasks are interpreted, not verified current job titles at this plant.
  • Instrumentation and controls

    Keep a process measurable and responsive. Controls work connects sensors, decisions and actuators so the system can respond when conditions change.

    Classroom connection
    Feedback uses a measured result to inform the next action.

    Job titles to search
    Instrumentation technician · Controls technician · Controls engineer

    Company supports HVAC manufacturing and service; SAIT supports general refrigeration/control work. The proposed tasks are interpreted, not verified current job titles at this plant.

Cards distinguish work documented at ICE Western from related work at other employers. Dated accounts and postings are not a current staff roster or a promise of a vacancy.

Ways in

For your students

Ways to prepare for this work

Programs that teach skills this work uses. Each is one route in, not a requirement, and no program has endorsed this page.

  • SAITApprenticeship technical trainingCalgary

    Refrigeration and Air Conditioning Mechanic

    Install, maintain and troubleshoot refrigeration and air systems.

    About this route

    Combine employer-based apprenticeship experience with technical training; check current provincial entry requirements. Check current admissions and intake before applying; this draft does not promise entry or employment.

    Why it connects to the work · our interpretation

    Refrigeration and air-conditioning mechanic

    Install, maintain and troubleshoot refrigeration and air systems. A refrigeration system moves heat; it does not create cold as a substance.

  • SAITDiplomaCalgary

    Mechanical Engineering Technology

    Design, modelling and mechanical-system analysis.

    About this route

    A technical route; does not itself confer professional engineer registration. Check current admissions and intake before applying; this draft does not promise entry or employment.

    Why it connects to the work · our interpretation

    Mechanical design and prototyping

    Design, modelling and mechanical-system analysis. A model is useful when its assumptions are clear and measurements can challenge it.

    Instrumentation and controls

    Design, modelling and mechanical-system analysis. A reading depends on where and how it was measured, not just the number displayed.

  • SAITDiplomaCalgary

    Instrumentation Engineering Technology

    Measurement, calibration and process controls.

    About this route

    Related to sensor/control work; no guaranteed employer placement. Check current admissions and intake before applying; this draft does not promise entry or employment.

    Why it connects to the work · our interpretation

    Instrumentation and controls

    Measurement, calibration and process controls. A reading depends on where and how it was measured, not just the number displayed.

Ask the class

Use it in class

Ask the class

Why might a designer choose separate air streams even if a simpler arrangement seemed easier to build?

Sketch exhaust at 20°C and outdoor air at −10°C, without assigning an output temperature. Mark energy-flow directions and list the measurements needed to estimate recovery. Identify why flow rates matter as well as temperature.

Mindset it shows

This is a run-around heat-recovery model, not every type of HVAC system. Do not depict dirty exhaust mixing directly with supply air or claim that a heat exchanger is a refrigerator. No glycol concentrations or equipment sizing instructions are needed.

About ICE Western

Fresh air can enter a building while some outgoing heat is recovered.

Headquarters
Headquarters not separately verified for this example.
Local connection
Employer identifies industrial manufacturing facility in Calgary's South Foothills.
Source: icewestern.com — official website(opens in a new tab); icewestern.com — Glycol_Runaround.pdf(opens in a new tab); icewestern.com — careers(opens in a new tab)
Team size
Not verified. We have not found a dated, sourced figure.
Who uses it
Building and industrial operators managing ventilation and temperature requirements.
Source: icewestern.com — official website(opens in a new tab); icewestern.com — Glycol_Runaround.pdf(opens in a new tab); icewestern.com — careers(opens in a new tab)

ICE Western describes a manufacturing facility in Calgary's South Foothills and products for custom air handling and heat recovery. An employer-hosted technical catalogue describes a run-around arrangement using coils connected by a circulating liquid loop. That arrangement provides a specific teaching model: transfer heat between air streams while keeping the streams separate. The archived catalogue is technical context, not proof of today's orderable configuration.

Source: icewestern.com — official website(opens in a new tab); icewestern.com — Glycol_Runaround.pdf(opens in a new tab); icewestern.com — careers(opens in a new tab)
Who does this work

Read each source’s date and scope: a documented role is not proof of a current vacancy or of where every position is based.

Reported as ICE Western states it. ICE Western has not reviewed or endorsed this page.

Sources and course fit

Sources checked 18 Oct 2026

Organization claims are reported as the organization states them. ICE Western has not reviewed or endorsed this page.

What we know, and how
TypeClaimHow we know
workICE Western describes a manufacturing facility in Calgary's South Foothills and products for custom air handling and heat recovery. An employer-hosted technical catalogue describes a run-around arrangement using coils connected by a circulating liquid loop. That arrangement provides a specific teaching model: transfer heat between air streams while keeping the streams separate. The archived catalogue is technical context, not proof of today's orderable configuration.Source: icewestern.com — official website; icewestern.com — Glycol_Runaround.pdf; icewestern.com — careersCompany-stated work with source limits preserved
local connectionEmployer identifies industrial manufacturing facility in Calgary's South Foothills.Source: icewestern.com — official website; icewestern.com — Glycol_Runaround.pdf; icewestern.com — careersSource-backed Calgary connection
course fitDirect thermal-system and efficiency connection. Coil sizing, airflow design and commercial ventilation requirements are extensions.Source: education.alberta.ca — science10.pdfEditorial application of source-checked curriculum concepts
limitsCatalogue path is historical (2011); use only its general heat-transfer relationship. Confirm current product configuration before any branded technical claim. Science 10 badge refers to energy concepts, not trade qualification.Source: icewestern.com — official website; icewestern.com — Glycol_Runaround.pdf; icewestern.com — careersScope of this example

Solid green: the organization states it. Outlined: seen in a dated source. Dashed: our interpretation, not yet researched, or announced but not yet real.